Stage Timing

Functions → Timing → Stage

Stage Timing measures one continuous segment from start to finish — stage rally, hill climb, or any point-to-point run. It does not count laps. Runs save to the Timing Run Library.

Enabling

Check Enable and set the speed channel (km/h). Distance can be integrated from speed or read from a distance channel.

Arm, start, finish, abort

StageTypical use
ArmStaging before the clock (switch, edge/level conditions, event, or Auto).
StartClock starts (start line event, green light, or conditions).
FinishClock stops. Prefer Event mapped to a Finish Beacon from a geo finish line under Locations & lines, or a dedicated finish event.
AbortCondition, event, or speed-drop while running.

Unlike circuit timing, stage does use Finish Beacon for the finish line. Circuit S/F uses Lap Beacon only.

Live delta

Stage Time Delta is distance-matched against the stage run set as reference in the Run Library (current time − reference time at the same distance). Negative means ahead of the reference.

  • Requires a saved trajectory on the reference run.
  • There is no fixed “manual reference time” in stage config — use the library.
  • Without a usable reference trajectory, Stage Time Delta stays invalid (blank/NaN).

Output channels

ChannelDescription
Stage StateDisabled / Idle / Armed / Running / Finished / Aborted
Stage TimeElapsed stage time
Stage DistanceDistance covered
Stage Time DeltaLive distance-matched Δ vs library reference

Events: Stage Start, Stage Finish, Stage Abort (when those transitions occur).