Tables

Functions → Tables

A table looks up an output from one input (1D) or two inputs (2D). The display reads the live input channels, interpolates between cells, and writes the result to the Output Channel. Maths, gauges, logging, and CAN transmit can use that channel.

There is no fixed limit on how many tables you can add. EmVision and EmStream use this same grid for analysis and live telemetry. On the display, the table runs continuously and the output is part of the configuration you write to the device.

Add a table

  1. Open Functions → Tables.
  2. Click Add Table.
  3. Set Name and Output Channel.
  4. If the grid says Axes Not Configured, click Configure Axes (or press A).

Right-click a table in the list to Cut, Copy, Paste, or Delete it. Drag tables to reorder them. Delete Table removes the selected table after you confirm.

The toolbar on the grid can load and save one table’s configuration, and toggle a surface plot of the cells.

Axes

Each axis has a Channel and a row of breakpoints.

ControlAction
Add / Insert / DeleteChange the number of cells on that axis
ClearRemove the breakpoints
GenerateFill breakpoints from Start, Step, and Max

An axis with no Y channel is a 1D lookup. Set both X and Y for a 2D table. After you change breakpoints, Studio can offer to interpolate the cell values so they follow the new headings.

Editing cells

Click a cell and type a value. Select a block of cells for the operations below. Right-click the grid for the full menu.

ActionShortcut
Interpolate both waysI
Interpolate across the rowR
Interpolate down the columnC
Smooth the selectionS
Select allCtrl+A
Copy / paste the selectionCtrl+C / Ctrl+V
Copy / paste the whole tableCtrl+Shift+C / Ctrl+Shift+V
Nudge the selectionPage Up / Page Down
Larger nudgeShift+Page Up / Shift+Page Down

Fill copies the edge of the selection up, down, left, or right. Extrapolate continues the slope past the selection in one of those directions.

Interpolating, nudging, or filling a large selection applies immediately. Undo restores that whole change in one step.

Sharing with EmVision and EmStream

Tables on the display are stored in the display configuration. To move the same tables into log analysis or the pit-wall PC, export them from EmVision or EmStream as an .emmtc setup pack (maths, user channels, and tables together). The grid tools on those apps match this page.