CAN Parameter Scaling

InfoAll values are 16 bit unsigned intergers, LSB Byte Order InfoUnlisted runtimes are raw
TypeMultiplierOffsetUnit
Lambda0.0010Lambda
Lambda Target Error0.001-10Lambda
STFT/LTFT0.01-100%
Cam Position0.1-200Degree
MGP0.1-100KPA
Fuel/Oil Pressure0.10KPA
PPS/TPS/Motor Position0.1-100%
VE0.10%
IdleP0.10%
PP/TP Error0.10%
DBW Target Error0.1-100%
Injector duty0.10%
Inj PW0.0010ms
F/I Cut0.10%
Speed KPH0.10KPH
RPM ROC1-20000RPM/second
PP/TP ROC0.1-100%/second
ECU G0.01-10G
Ignition angle0.1-100Degree
Ignition trims0.1-100Degree
FP Diff Offset0.1-1000KPA
Voltage0.0010Voltage
Drive Slip0.01-100%
Temps0.1-50Degrees C
Fuel Level0.10Liters
Fuel used0.010Liters
Gear1-10Gear
Time Milliseconds0.010Milliseconds
Time Seconds0.10Seconds
Time Min10Min
Force0.1-100KG
Mass flow /Sec0.10G/s
Mass flow /Cyl0.0010G/cyl
Traction Target0.10%
Traction Target Error0.1-100%
Power10KW
Torque1-1000NM
Torque Reduction (Frictional loss)-10NM
Vehicle Accel (M/S/S)0.01-100m/s/s
Vehicle Accel (KM/HR/S)0.01-100km/hr/s