<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Bandwidth Considerations :: Emtron Resource Centre</title><link>https://docs.emtronaustralia.com.au/engine-management/config/communications/bandwidth-considerations1/index.html</link><description>Bus bandwidth needs to be considered when data is transmitted over CAN. The ECU has Transmit rates from 10Hz up to 1000Hz.
Example 1:
The following uses the Predefined 1 Tx DATA set. This uses 10 sequential addresses and it total transmits the value of 40 parameters. CAN Baud rate at 1Mbps
Tx Rate Number of Messages Bandwidth Used (%) Available Bandwidth for other devices 10Hz 10 1.2% 98.8% 50Hz 10 6.1% 93.9% 100Hz 10 12.2% 87.8% 500Hz 10 61% 39% 1000Hz 10 Cannot be achieved Example 2:</description><generator>Hugo</generator><language>en-us</language><atom:link href="https://docs.emtronaustralia.com.au/engine-management/config/communications/bandwidth-considerations1/index.xml" rel="self" type="application/rss+xml"/></channel></rss>