Gear Cut End Source

Gear Cut End Source

This setting controls the way the cut is to be ended once triggered. The following settings are available :

0: Timed Setting uses the Cut Time Table to

control the Cut length

1: “Clutch Switch” Status changing to OFF ends

the Cut

2: “Gear Cut Switch” Status changing to OFF ends

the Cut

3: If Positive Force Started the cut, the cut End

will occur when the Force is less than the

Postive Force Threshold - Gear Cut Force Hysteresis.

The inverse applies for a Negative Force Start Cut

Example:

Force Threshold = 8.0kg

Gear Cut Force Hysteresis = 3.0kg

Start Cut at > 8.0 kg

End Cut at < 5.0 kg

Force Threshold = -6.0kg

Gear Cut Force Hysteresis = 3.0kg

Start Cut at > -6.0 kg

End Cut at < -3.0 kg

NOTE: “Gear Cut Start Source” MUST be

selected as 2 (Gear Shift Force) for this setting

to work

4: Next Gear Stable will determine the cut time. Once

the next gear is confirmed the ECU will initiate a cut end