<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Lambda Control Setup :: Emtron Resource Centre</title><link>https://docs.emtronaustralia.com.au/engine-management/functions/lambda-control/lambda-control-setup/index.html</link><description>Lambda Control Setup Engine Temp Lockout - Engine temp above which Lambda Control can become active RPM Lo Lockout - Lambda control will be switched OFF below this RPM RPM Hi Lockout - Lambda control will be switched OFF above this RPM Recovery Delay - Delay in which Lambda Control can become active once within the lockout criteria Post Start Delay - Delay in which Lambda Control can become active after start up d**** NOTE: When using the Internal Lambda the Closed Loop will not start until either or both sensors are ready to operate.</description><generator>Hugo</generator><language>en-us</language><atom:link href="https://docs.emtronaustralia.com.au/engine-management/functions/lambda-control/lambda-control-setup/index.xml" rel="self" type="application/rss+xml"/></channel></rss>