Timers
Timers
The following calculated runtimes are generated by Emtron that are Timer related (to be further discussed more specifically):
- User Timers - Status of User Timers
- Crank Exit Timer - Time counter after cranking
- Crank Timer - Time count during cranking
- Firing Events Counter - Count of engine firing events
- Engine Cycle Counter - Count of engine cycles
- Engine Runtime - Engine runtime
- ECU Runtime - ECU on runtime
- TPS WOT Timer - Time throttle position is wide open
- TPS Closed Timer - Time throttle position is closed
- MAP High Timer - Time manifold pressure is high
- Gear Cut Timer - Gear cut duration
- Pedal Closed Timer - Time pedal position is closed
- Race Timer - Race timer
- Gearshift Cut Start - Gearshift time from cut start
- Gearshift Next Gear - Gearshift time to next gear
- Upshift Measured - Measured upshift time
- Downshift Measured - Measured downshift time
- Anti-Lag Disarm - Disarm timer for Anti-Lag
Many of these timers are pre-configured and function automatically.
User Timers
Timers must be enabled Config > Function Setup > Timer Functions
User Timer Setup
Timers are configured in the Tuning section
Tuning > Timer Functions Configuring timer 1-5 opens up a configuration window to set conditions, max time, and Timer Reset Mode
Set the conditions for the timer to start using Emtron ECU runtimes or status. There are up to 4 conditions that can be used to start the timer.
Max Time
Set the max time the timer can count
Timer Reset Mode
Reset when Timer Function turns OFF
The timer will reset when the conditions are no longer met
Example:
Timer condition is >3000 rpm, the timer will reset every time the engine speed falls below 3000rpm.
Reset when Timer Function turns ON
The timer will reset when the conditions are met again
Example:
Timer condition is >3000 rpm, the timer will reset when the engine speed falls below 3000rpm, and then goes past it again
Never
The timer will not reset
Fixed Timer Setup
Fixed Timers are configured in the Tuning section
- Tuning, Timer Functions, Fixed Timer Setup
TP1 WOT Timer ON
Set what position TP1 needs to surpass to start counting TP WOT time
TP1 Closed Timer ON
Set what position TP1 needs to be below to start counting TP Closed time
MAP High Timer ON
Set what kPa MAP needs to surpass to start counting MAP High time
PP1 Closed Timer (pp1)
Set what position PP1 needs to be below to start counting PP Closed time
PP1 Closed Timer (rpm)
Set what RPM needs to be below to start counting PP Closed time
Race Timer Start Mode
Select from the following to trigger the Race Timer to start or create a custom function using a User Output
Race Timer Max Time
Max time for Race Timer
Race Timer Reset Mode