Decel Sens Table
Decel Sens Table
The Decel Sensitivity Table is the multiplication factor as a percentage of fuel removed, based on the rate of change of the Accel/Decel mode
Note: Must be set to PP or TP
Example:
dTP1 = 10%
Decel Sense = 10%
Fuel base pulse width = 5.0ms
Decel PW = 10*0.10 = 1.0ms
Total fuel pulse width = 5.0 – 1.0 = 4.0ms