Emtron Lambda to CAN (ELC/ELCM) Setup
For details :
Emtron Lambda CAN Manual
Click the link below to download or visit Emtron www Downloads
ELC
Reset CAN IDs to Default
0: OFF
1: ON
This will reset the ELC CAN IDs back to their default values
Channel 1 = 671, Channel 2 = 672
Set back to zero when finished.
Enable Heater Override
0: OFF
1: ON
When enabled, the ECU controls when the Lambda heater is ON or OFF. This is done through the “ELC HEater RPM Lockout” and “ELC Heater Post Start Lockout: settings.
When disable the ELC controls the heater(s) which will turn On 15 secs after the device power up.
Enable EMAP
0: OFF
1: ON
When enabled, the ECU will send EMAP data to the ELC. This units should be in kPa
** When enabled please make sure the EMAP is configured correctly inside the ECU.
ELC Heater RPM Lockout
RPM Below which heater will be locked out
ELC Heater Post Start Lockout
Timer before which heater will turned on Post Start up
ELC Lambda 1 Test Enable
Forces the ELC to send this Test Value over the CAN bus.
Allows the user to confirm the ECU calibration is setup correctly.
0 = OFF
ELC Lambda 2 Test Enable
Forces the ELC to send this Test Value over the CAN bus.
Allows the user to confirm the ECU calibration is setup correctly.
0 = OFF