Cam Lockouts

CAM Lockouts

Image Image

Image Image

RPM Lockout 

RPM Lockout

Engine speed above which Cam Control is set to become active

Typical : 500 RPM

Engine Temp Lockout

Engine Temp above which Cam Control is set to become active.

Typical : 60 degC

VVT Startup Lockout

Delay timer from Crank RPM Exit before VVT Cam Control is permitted to become active. 

This setting helps prevent the Cam Control Solenoid “Rattling” at startup due to low oil pressure.

Typical : 500 RPM