Log Adjustments
Log adjustments change how a channel is drawn and read in EmVision. They do not rewrite the samples inside the log file.
Scale and offset are saved in a .ely file beside the log (run.elo keeps run.ely). Open the log again and those adjustments come back. Notes, the linked video, and session constant overrides live in the same file. A low-pass filter is kept for this EmVision session, including if you close the log and open it again, and is left out of the .ely.
The Log adjustments button on an open log turns blue when that log has any adjustment. The same command is in the log’s ⋮ menu.
From a line plot
Right-click a channel name in the line plot legend.
| Command | Effect |
|---|---|
| Hide / Show | Takes that trace off the plot, or puts it back. The channel stays in the plot setup |
| Remove | Asks before taking the channel off the plot |
| Edit Maths | Opens the maths editor when the channel is a math channel |
| Scale & Offset… | Sets value × scale + offset for this channel on this log |
| Zero at Cursor | Shifts the offset so the value at the cursor reads zero |
| Filter | Low-pass at 1, 2, 5, 10, or 20 Hz, or Custom… for another cutoff |
| Properties… | Opens that channel in plot setup |
| Clear adjustments | Puts scale back to 1, offset back to 0, and clears the filter |
| Units | Shows the channel in another unit on this plot |
A small mark stays on the name while a scale, offset, or filter is applied. The Filter menu stays ticked on the cutoff you chose.
Hide and Remove change the plot. Scale, offset, zero, and filter change the channel on that log, so the measurements panel, statistics, and other plots see the same numbers.
Log adjustments dialog
Log adjustments on the open log lists every channel:
- Notes — free text stored with the log
- Search — narrows the list.
*is a wildcard, soPDM1*VoltagematchesPDM1 Output 7 Voltage - Scale and Offset — edit either value. The row is highlighted while it differs from 1 and 0
- Reset on a row — clears that channel
- Reset all… — asks before clearing every scale and offset on the log
What uses the adjusted value
Plots, the cursor readout, statistics, the lap matrix, and maths that read the channel use the scaled and offset value, in the unit you are viewing. Comparison logs keep their own .ely files.
Export writes the log’s samples and any maths or table channels you select. It does not modify the original file, and it does not write the .ely into the export.